Members
Overall Objectives
Research Program
Application Domains
Highlights of the Year
New Software and Platforms
New Results
Bilateral Contracts and Grants with Industry
Partnerships and Cooperations
Dissemination
Bibliography
XML PDF e-pub
PDF e-Pub


Section: New Results

Diffusion MRI

Adapting the Kärger model to account for finite diffusion-encoding pulses in diffusion MRI

H. Haddar, J.R. Li and S. Schiavi

Diffusion magnetic resonance imaging (dMRI) is an imaging modality that probes the diffusion characteristics of a sample via the application of magnetic field gradient pulses. If the imaging voxel can be divided into different Gaussian diffusion compartments with inter-compartment exchange governed by linear kinetics, then the dMRI signal can be described by the Kärger model, which is a well-known model in NMR. However, the Kärger model is limited to the case when the duration of the diffusion-encoding gradient pulses is short compared to the time delay between the start of the pulses. Under this assumption, the time at which to evaluate the Kärger model to obtain the dMRI signal is unambiguously the delay between the pulses. Recently, a new model of the dMRI signal, the Finite-Pulse Kärger (FPK) model, was derived for arbitrary diffusion gradient profiles. Relying on the FPK model, we show that when the duration of the gradient pulses is not short, the time at which to evaluate the Kärger model should be the time delay between the start of the pulses, shortened by one third of the pulse duration. With this choice, we show the sixth order convergence of the Kärger model to the FPK model in the non-dimensionalized pulse duration.

A macroscopic model for the diffusion MRI signal accounting for time-dependent diffusivity

H. Haddar, J.R. Li and S. Schiavi

An important quantity measured in dMRI in each voxel is the Apparent Diffusion Coefficient (ADC) and it is well-established from imaging experiments that, in the brain, in-vivo, the ADC is dependent on the measured diffusion time. To aid in the understanding and interpretation of the ADC, using homogenization techniques, we derived a new asymptotic model for the dMRI signal from the Bloch-Torrey equation governing the water proton magnetization under the influence of diffusion-encoding magnetic gradient pulses. Our new model was obtained using a particular choice of scaling for the time, the biological cell membrane permeability, the diffusion-encoding magnetic field gradient strength, and a periodicity length of the cellular geometry. The ADC of the resulting model is dependent on the diffusion time. We numerically validated this model for a wide range of diffusion times for two dimensional geometrical configurations.

Quantitative DLA-based Compressed Sensing for MEMRI Acquisitions

P. Svehla, K.-V. Nguyen, J.-R. Li and L. Ciobanu

High resolution Manganese Enhanced Magnetic Resonance Imaging (MEMRI) has great potential for functional imaging of live neuronal tissue at single neuron scale. However, reaching high resolutions often requires long acquisition times which can lead to reduced image quality due to sample deterioration and hardware instability. Compressed Sensing (CS) techniques offer the opportunity to significantly reduce the imaging time. The purpose of this work is to test the feasibility of CS acquisitions based on Diffusion Limited Aggregation (DLA) sampling patterns for high resolution quantitative MEMRI imaging. Fully encoded and DLA-CS MEMRI images of Aplysia californica neural tissue were acquired on a 17.2T MRI system. The MR signal corresponding to single, identified neurons was quantified for both versions of the T1 weighted images. Results: For a 50% undersampling, DLA-CS leads to signal intensity differences, measured in individual neurons, of approximately 1.37% when compared to the fully encoded acquisition, with minimal impact on image spatial resolution. At the undersampling ratio of 50%, DLA-CS is capable of accurately quantifying signal intensities in MEMRI acquisitions. Depending on the image signal to noise ratio, higher undersampling ratios can be used to further reduce the acquisition time in MEMRI based functional studies of living tissues.

The time-dependent diffusivity in the abdominal ganglion of Aplysia californica, comparing experiments and simulations

K.-V. Nguyen, D. Le Bihan, L. Ciobanu and J.-R. Li

The nerve cells of the Aplysia are much larger than mammalian neurons. Using the Aplysia ganglia to study the relationship between the cellular structure and the diffusion MRI signal can shed light on this relationship for more complex organisms. We measured the dMRI signal at several diffusion times in the abdominal ganglion and performed simulations of water diffusion in geometries obtained after segmenting high resolution T2-weighted images and incorporating known information about the cellular structure from the literature. By fitting the experimental signal to the simulated signal for several types of cells in the abdominal ganglion at a wide range of diffusion times, we obtained estimates of the intrinsic diffusion coefficient in the nucleus and the cytoplasm. We also evaluated the reliability of using an existing formula for the time-dependent diffusion coefficient to estimate cell size.

A two pool model to describe the IVIM cerebral perfusion

G. Fournet, J.-R. Li, A.M. Cerjanic, B.P. Sutton, L. Ciobanu and D. Le Bihan

IntraVoxel Incoherent Motion (IVIM) is a magnetic resonance imaging (MRI) technique capable of measuring perfusion-related parameters. In this manuscript, we show that the mono-exponential model commonly used to process IVIM data might be challenged, especially at short diffusion times. Eleven rat datasets were acquired at 7T using a diffusion-weighted pulsed gradient spin echo sequence with b-values ranging from 7 to 2500 s/mm² at 3 diffusion times. The IVIM signals, obtained by removing the diffusion component from the raw MR signal, were fitted to the standard mono-exponential model, a bi-exponential model and the Kennan model. The Akaike information criterion used to find the best model to fit the data demonstrates that, at short diffusion times, the bi-exponential IVIM model is most appropriate. The results obtained by comparing the experimental data to a dictionary of numerical simulations of the IVIM signal in microvascular networks support the hypothesis that such a bi-exponential behavior can be explained by considering the contribution of two vascular pools: capillaries and somewhat larger vessels.

The influence of acquisition parameters on the metrics of the bi-exponential IVIM model

G. Fournet, J.-R. Li, D. Le Bihan and L. Ciobanu

The IntraVoxel Incoherent Motion (IVIM) MRI signal, typically described as a mono-exponential decay, can sometimes be better modeled as a bi-exponential function accounting for two vascular pools, capillaries and medium-size vessels. The goal of this work is to define precisely in which conditions the IVIM signal shape becomes bi-exponential and to understand the evolution of the IVIM outputs with different acquisition parameters. Rats were scanned at 7T and 11.7T using diffusion-weighted pulsed-gradient spin-echo (SE) and stimulated-echo (STE) sequences with different repetition times (TR) and diffusion encoding times. The obtained IVIM signals were fit to the mono- and bi-exponential models and the output parameters compared. The bi-exponential and mono-exponential models converge at long diffusion encoding times and long TRs. The STE is less sensitive to inflow effects present at short TRs, leading to a smaller volume fraction for the fast pool when compared to the SE sequence. The two vascular components are more easily separated at short diffusion encoding times, short TRs and when using a SE sequence. The volume fractions of the two blood pools depend on the pulse sequence, TR and diffusion encoding times while the pseudo-diffusion coefficients are only affected by the diffusion encoding time.