Section: New Results

Metastability-Aware Memory-Efficient Time-to-Digital Converter

Published in [11].

We propose a novel method for transforming delay- line time-to-digital converters (TDCs) into TDCs that output Gray code without relying on synchronizers. We formally prove that the inevitable metastable memory upsets (Marino, TC'81) do not induce an additional time resolution error. Our modified design provides suitable inputs to the recent metastability-containing sorting networks by Lenzen and Medina (ASYNC'16) and Bund et al. (DATE'17). In contrast, employing existing TDCs would require using thermometer code at the TDC output (followed by conversion to Gray code) or resolving metastability inside the TDC. The former is too restrictive w.r.t. the dynamic range of the TDCs, while the latter loses the advantage of enabling (accordingly much faster) computation without having to first resolve metastability.